CAT6A Plenum ETL Listed Shielded F/UTP 23AWG CMP 1000ft Spool

Designed for air-handling spaces, this Cat6a plenum cable features a CMP-rated jacket and 23AWG solid bare copper conductors. It supports data speeds up to 10Gbps with 750MHz bandwidth. The F/UTP shielded 4-pair design helps reduce electromagnetic interference, making it suitable for enterprise networks and commercial installations requiring dependable high-speed data transmission.

In stock

SKU
NYC-V63x-ETL-FTP
Material
Plenum Jacket, Copper Conductors
Color:
As low as: $12.00
For Bulk Orders Call Us Now
Feature Details
Material Plenum Jacket, Copper Conductors
General Type F/UTP
Cable Category Cat6a
Category Type Ethernet Cables
Speed 10 Gbps
Frequency 750 MHz
Conductor Diameter 23AWG
Jacket Rating CMP (Plenum)
Cable Length 1000 feet
Conductor Material 100% Pure Copper
Special Features EMI-Reduction, Heat-Resistant, High-Speed, Tangle-Free, UV-Resistant
For Use Vertical Installations
Connector Type RJ45
Packaging Wooden Spool
Certifications ETL, FCC, CE, ISO/IES, RoHS
PoE Compatibility 802.3af/at/bt Type 4
Twisted Pair Colors Pair 1: Blue, White-Blue Pair 2: Orange, White-Orange Pair 3: Green, White-Green Pair 4: Brown, White-Brown
Shielding F/UTP (Foil Shielded)

Enterprise Grade CAT6A Shielded Plenum Cable

  • Cat6a F/UTP shielded cable
  • 23 AWG solid bare copper
  • 750 MHz bandwidth support
  • Foil shielding for EMI reduction
  • Designed for enterprise networks

High-Speed 10 Gigabit Performance

  • Supports 10 Gigabit Ethernet
  • Handles high bandwidth demands
  • Supports modern network upgrades
  • Suitable for data center networks
  • Built for reliable data transmission

Certified CMP Plenum Safety

  • CMP rated plenum jacket
  • Suitable for air handling spaces
  • Helps limit flame spread
  • Helps reduce smoke emissions
  • Ideal for commercial installations

ETL Listed Cable Quality

  • ETL Listed for quality assurance
  • Designed for Cat6A applications
  • Supports professional installations
  • Suitable for enterprise networks
  • Built for certifications demanding projects

Shielded Pure Copper Construction

  • Solid bare copper conductors
  • 23 AWG conductor size
  • F/UTP foil shielding
  • Four twisted copper pairs
  • Supports stable signal transmission

Easy 1000ft Spool Installation

  • 1000ft cable length
  • Convenient spool packaging
  • Easy cable handling
  • Supports controlled cable pulls
  • Suitable for larger installations

Future-Ready 10G Performance

ThisCat6a plenum shielded cable  is engineered to support high-speed 10 Gigabit Ethernet applications. With a 750 MHz rating, it provides additional bandwidth for modern networking needs. The F/UTP shielding helps reduce electromagnetic interference, while the solid bare copper conductors support consistent signal transmission.
This Cat6a shielded cable is suitable for data centers, enterprise networks, and other high-demand environments.

CMP Plenum Safety and Compliance

The Cat6a F/UTP CMP cable features a plenum-rated jacket designed for air-handling spaces such as drop ceilings and HVAC systems. It helps limit flame spread and smoke emissions during fire events.
Our Cat6a plenum ETL listed shielded cable is a suitable choice for commercial and institutional installations where fire safety requirements are important.

Superior Shielded Copper Performance

Built with 23 AWG solid bare copper conductors, this Cat6a shielded pure copper cable supports reliable signal transmission and consistent network performance. The F/UTP foil shield provides an additional layer of protection against electromagnetic interference.
Our Cat6a plenum cable supports PoE, PoE+, and PoE++ applications under IEEE 802.3af, 802.3at, and 802.3bt Type 4. This allows compatible network devices to receive both data and power through the Ethernet connection.
Unlike copper-clad aluminum (CCA), solid copper is a suitable choice for professional networking applications where conductivity and long-term reliability matter.

Buy CAT6A Plenum ETL-Listed Shielded Cable | NewYork Cables

Our Cat6a plenum shielded cable solutions are designed for performance, safety, and reliable installation. This 1000ft Cat6a F/UTP cable combines ETL listing, solid bare copper conductors, 750 MHz bandwidth, and a CMP-rated jacket for demanding commercial networks.

Request a quote now or get in touch with us for more information.

Customer Reviews

Quality
Review by
I was replacing an older network cable in our office and needed something that could handle our new equipment. This worked out better than expected. The cable is a little heavier because of the shielding, but it still pulled nicely. We also needed CMP rated cable for the ceiling space, so that was important for us. Everything is working fine after the installation.
Quality
Review by
I bought this for a larger network job and honestly I don't have much to complain about. Cable feels strong and the spool was packed good. The shielding and ETL listing was one of the main reasons I picked it. Data connection has been stable so far.
Quality
Review by
Pretty happy with this cable. We needed shielded Cat6a cable for a project and this one checked all the boxes. Its solid copper and not CCA which was important to us. Pulling the cable was easy enough. Overall a good product and the network is running great.
Quality
Review by
Good cable. Solid copper, shielded, ETL listed and easy to pull from the spool. No problems during installation. Order also arrived fast.
Quality
Value
Price
Review by
Installed this in our office network last month. The 1000ft spool was enough for most of the work and made it easier to measure and cut the runs. Cable quality feels very good. We have not had any connection issues since finishing the job. I would use it again.
Write Your Own Review
You're reviewing: CAT6A Plenum ETL Listed Shielded F/UTP 23AWG CMP 1000ft Spool
Your Rating:
loader
Loading...

You submitted your review for moderation.

What makes Cat6a Ethernet cable different from standard Cat6 Ethernet cable?
Cat6a Ethernet cable offers higher bandwidth at 750 MHz and is designed to support 10 Gigabit Ethernet over longer distances. It is often selected for enterprise networks, data centers, and other high-performance applications.
Why would I choose a shielded Cat6a cable instead of an unshielded cable?
Cat6a F/UTP cable includes an overall foil shield that helps reduce electromagnetic interference (EMI). This makes it a good choice for installations near electrical equipment, power cables, or other sources of signal disruption.
Can this cable be installed in air-handling spaces?
Yes. Cat6a CMP plenum cable is designed for installation in air-return spaces such as drop ceilings and HVAC pathways where plenum-rated cable is required by building codes.
What does the 750 MHz rating mean?
The Cat6a shielded Ethernet cable is tested to support frequencies up to 750 MHz. Higher bandwidth capacity helps accommodate demanding network traffic and future network upgrades.
Is Cat6a plenum shielded cable a good choice for data centers?
Yes. Cat6a plenum shielded cable is commonly used in data centers because it supports high-speed network connections, helps reduce interference, and offers reliable performance for critical infrastructure.
Does the foil shielding eliminate the need for proper cable routing?
No. While Cat6a shielded CMP cable helps reduce EMI, following proper installation practices, maintaining bend radius, and avoiding unnecessary cable stress are still important for optimal performance.
Do I need shielded connectors with Cat6a F/UTP cable?
For best results, Cat6a F/UTP plenum cable should be used with compatible shielded connectors, keystone jacks, and patch panels. This helps maintain shielding continuity throughout the network link.
How does a plenum-rated jacket improve safety?
The jacket used on Cat6a plenum-rated cable is designed to help limit flame spread and reduce smoke generation in the event of a fire, making it suitable for plenum spaces.
Is Cat6a bulk plenum cable suitable for high-density network environments?
Yes. Cat6a bulk plenum cable is well suited for enterprise offices, server rooms, educational campuses, and other environments with large numbers of connected devices and high bandwidth requirements.
Does shielded Cat6a cable require grounding?
Yes. Cat6a shielded cable should be properly grounded using appropriate networking hardware. Correct grounding helps the shielding effectively reduce interference and maintain signal integrity.